Port Setup
Port Setup
Use this screen to configure Switch port settings. Click PORT > Port Setup > Port Setup in the navigation panel to display the configuration screen.
PORT> Port Setup > Port Setup (Standalone Mode)
PORT > Port Setup > Port Setup (Stacking Mode)
The following table describes the labels in this screen.
PORT > Port Setup > Port Setup 
label
description
SLOT
This field appears only in Stacking mode. Click the drop-down list to choose the slot number of the Switch in a stack.
Port
This is the port index number. In Stacking mode, the first number represents the slot ID and the second one is the port number. Please note that the default stacking ports (the last four ports of your Switch) cannot be configured. They are reserved for stacking only.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set the common settings and then make adjustments on a port-by-port basis.
*Changes in this row are copied to all the ports as soon as you make them.
Active
Select this checkbox to enable a port. The factory default for all ports is enabled. A port must be enabled for data transmission to occur.
Name
Type a descriptive name that identifies this port. You can enter up to 128 printable ASCII characters except [ ? ], [ | ], [ ' ] or [ " ].
*Due to space limitations, the port name may be truncated in some Web Configurator screens.
Speed/Duplex
Select the speed and the duplex mode of the connection on this port.
For an Ethernet port, the choices are Auto, 10-an (10M/auto-negotiation), 100-an (100M/auto-negotiation), Auto-1G, 10M / Half Duplex, 10M / Full Duplex, 100M / Half Duplex, 100M / Full Duplex, 1G / Full Duplex, 2.5G / Full Duplex, 5G / Full Duplex, and 10G / Full Duplex.
For an SFP fiber port, the choices are Auto, Auto-1G, 100M / Full Duplex, and 1G / Full Duplex.
For an SFP+ fiber port, the choices are Auto, Auto-1G, 1G / Full Duplex, and 10G / Full Duplex.
For an SFP28 fiber port, the choices are Auto, 1G / Full Duplex, 10G / Full Duplex, 25G-an (25G/auto-negotiation), and 25G / Full Duplex.
For an QSFP28 fiber port, the choices are 100G-an (100G/auto-negotiation), and 100G / Full Duplex.
Selecting Auto-1G or Auto (auto-negotiation) allows one port to negotiate with a peer port automatically to obtain the connection speed and duplex mode that both ends support. When auto-negotiation is turned on, a port on the Switch negotiates with the peer automatically to determine the connection speed and duplex mode. If the peer port does not support auto-negotiation or turns off this feature, the Switch determines the connection speed by detecting the signal on the cable and using half duplex mode. When the Switch’s auto-negotiation is turned off, a port uses the pre-configured speed and duplex mode when making a connection, therefore requiring you to make sure that the settings of the peer port are the same in order to connect.
FEC
To minimize signal degradation of data at high transmission speeds (for example, 25 Gbps or 100 Gbps), set the same FEC (Forward Error Correction) type between the Switch and the connected device.
Select Auto to allow both connected ports to automatically set the FEC type according to the following rules:
• For 10G transceivers, the FEC type on the port will automatically be None.
• For 25G transceivers, the FEC type on the port will automatically be CL108.
• For 100G transceivers, the FEC type on the port will automatically be None if the transceiver type is 100G LR4/ER4; all other types of transceiver will automatically be CL91.
Select CL74 when both connected ports support 25 Gbps speed and require low latency in data transmission.
Select CL91 when both connected ports support 25 Gbps and 100 Gbps speeds.
Select CL108 when both connected ports support 25 Gbps speed but low latency in data transmission is not required.
Alternatively, select None when you do not need to set the FEC type.
*Make sure to set the correct Speed/Duplex on this screen.
Flow Control
A concentration of traffic on a port decreases port bandwidth and overflows buffer memory causing packet discards and frame losses. Flow Control is used to regulate transmission of signals to match the bandwidth of the receiving port.
The Switch uses IEEE 802.3x flow control in full duplex mode.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to the sending port, causing it to temporarily stop sending signals when the receiving port memory buffers fill.
Select Tx Rx to allow the Switch port to send pause signal to the connected device, and for the connected device to send a pause signal to the Switch. The Switch will temporarily stop sending signals after receiving pause signal.
Select Tx to allow the Switch port to send pause signal to the connected device.
Select Rx to allow the connected device to send a pause signal to the Switch. The Switch will temporarily stop sending signals.
Otherwise, select Disable.
For the Switch model that do not support Tx Rx, Tx, or Rx, select Flow Control to enable it.
802.1p Priority
This priority value is added to incoming frames without a (802.1p) tag.
BPDU Ctrl
Configure the way to treat BPDUs received on this port. You must activate Bridging Control Protocol Transparency in the SYSTEM > Switch Setup > Switch Setup screen first.
Select Peer to process any BPDU (Bridge Protocol Data Units) received on this port.
Select Tunnel to forward BPDUs received on this port.
Select Discard to drop any BPDU received on this port.
Select Network to process a BPDU with no VLAN tag and forward a tagged BPDU.
*BPDU control is only available in Standalone mode.
Media Type
Select the media type (SFP+ transceiver or an SFP+ Direct Attach Copper (DAC) cable) on this port.
Select Auto for choosing the media type automatically based on the DDMI information. This is the default setting.
Select SFP+ for a SFP+ transceiver.
Select DAC10G for a DAC 10G module.
Select SFP28 for a SFP28 transceiver.
Select DAC25G for a DAC 25G module.
Select QSFP28 for a QSFP28 transceiver.
Select DAC100G for a DAC 100G module.
*Auto is only available for Zyxel transceivers and the Speed/Duplex field is set at Auto or 10G / Full Duplex.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these changes if it is turned off or loses power, so use the Save link on the top navigation panel to save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Technical Reference
This section provides technical background information on the topics discussed in this chapter.
CL (Clause) Types and Applications
The following table lists the types of FEC algorithms, also known as CLs (Clauses), and its applications.
CL (Clause) Types and Applications 
Clause
APPLICATION
CL74
Support for 25 Gbps transmission speed only. Select CL74 for applications that require real-time data transmission such as VoIP services. VoIP packets need to be prioritized to prevent dropped calls and ensure crystal-clear audio quality.
CL91
Support for both 25 Gbps and 100 Gbps transmission speeds. Select CL91 for applications that require 100 Gbps transmission speed. The 100 Gbps ports can use any of the following transceivers.
• 100 Gbps SR4. SR4 (Short Range 4) are for connections up to 100 meters over OM3 (Optical Fiber Cable Specification for Multi-Mode 3) fiber optic cables, or connections up to 150 meters over OM4 (Optical Fiber Cable Specification for Multi-Mode 4) fiber optic cables.
• 100 Gbps CR4. CR4 (Copper 4) are for connections up to 7 meters for passive DAC type transceivers, or connections up to 10 meters for active DAC type transceivers. Passive DAC type transceivers uses less than 0.15 watt of power. Active DAC type transceivers uses more power from 0.5 to 1.0 watt.
• 100 Gbps fan-out cable. A fan-out cable is a transceiver that can connect to four 25 Gbps devices. Use a fan-out cable to aggregate four 25 Gbps ports into one logical interface to provide higher bandwidth, load balancing, and link redundancy.
CL108
Support for 25 Gbps transmission speed only. Select CL108 for applications that do not require real-time data transmission such as web browsing, emails, file transfers and software updates.
FEC Types and Transceivers
The following table lists the FEC types and the corresponding types of transceivers to use.
FEC Types and Transceivers 
FEC TYPE
TRANSCEIVER TYPE
CL74
• 25G DAC CA-S 3m
• 25G AOC 1-10m
• 25G-CR CA-25G-S
CL91
• 25G DAC CA-L 5m
• 25G-CR CA-25G-L
The above two fan-out cable transceivers can connect to four 25 Gbps devices. A fan-out cable can aggregate four 25 Gbps ports into one logical interface, providing higher bandwidth, load balancing, and link redundancy.
• 100G-CR4 (Copper 4)
Use this for connections up to 7 meters for passive DAC type transceivers, or connections up to 10 meters for active DAC type transceivers. Passive DAC type transceivers uses less than 0.15 watt of power. Active DAC type transceivers uses more power from 0.5 to 1.0 watt.
• 100G-SR4 (Short Range 4)
Use this for connections up to 100 meters over OM3 (Optical Fiber Cable Specification for Multi-Mode 3) fiber optic cables, or connections up to 150 meters over OM4 (Optical Fiber Cable Specification for Multi-Mode 4) fiber optic cables.
CL108
• 25G-SR
• 25G-LR
• 25G-ER
None (No FEC)
• 10G
• 25G DAC CA-N 1-3m
• 25G-CR CA-25G-N
• 100G-LR4
• 100G-ER4
FEC Types and Negotiation Results
The following table lists the FEC types of transmitting and receiving ports and the result of connection speed and duplex negotiation at 25 Gbps and 100 Gbps transmission speeds.
FEC Types and Negotiation Results 
PORT A
Port B
NEGOTIATION RESULT
25 Gbps
CL108
CL108
CL108
CL74
CL74
CL74
None (No FEC)
None (No FEC)
None (No FEC)
None (No FEC)
CL108
CL108
None (No FEC)
CL74
CL74
CL74
CL108
CL108
100 Gbps
CL91
CL91
CL91
None (No FEC)
None (No FEC)
CL91
None (No FEC)
CL91
CL91