System Information
What You Can Do
Use the System Information screen (System Information) to view general system information and hardware status of the Switch.
System Information
In the navigation panel, click MONITOR > System Information > System Information to display the screen as shown. Use this screen to view general system information.
MONITOR > System Information > System Information (Standalone Mode)
MONITOR > System Information > System Information (Stacking Mode)
The following table describes the labels in this screen.
MONITOR > System Information > System Information 
label
description
System Information
System Name
This displays the descriptive name of the Switch for identification purposes.
Product Model
This displays the product model of the Switch. Use this information when searching for firmware upgrade or looking for other support information in the website.
FaOS F/W Version
This displays the version number of the Switch 's current firmware including the date created.
Ethernet Address
This refers to the Ethernet MAC (Media Access Control) address of the Switch.
CPU Utilization Current (%)
This displays the current percentage of CPU utilization.
Memory Utilization
Memory utilization shows how much DRAM memory is available and in use. It also displays the current percentage of memory utilization.
Name
This displays the name of the memory pool.
Total (byte/KB)
This displays the total number of bytes or kilobytes in this memory pool.
Used (byte/KB)
This displays the number of bytes or kilobytes being used in this memory pool.
Utilization (%)
This displays the percentage (%) of memory being used in this memory pool.
Hardware Monitor
Temperature Unit
The Switch has temperature sensors that are capable of detecting and reporting if the temperature rises above the threshold. You may choose the temperature unit (Centigrade or Fahrenheit) in this field.
Temperature (C/F)
BOARD, MAC, CPU, and PHY refer to the location of the temperature sensor on the Switch printed circuit board.
Status
This field displays Normal for temperatures below the threshold and Error for those above.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Fan Speed (RPM)
A properly functioning fan is an essential component (along with a sufficiently ventilated, cool operating environment) in order for the device to stay within the temperature threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed falls below the threshold shown.
Status
Normal indicates that this fan is functioning above the minimum speed. Error indicates that this fan is functioning below the minimum speed.
Current
This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX
This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).
MIN
This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Voltage(V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if the voltage falls out of the tolerance range.
Status
Normal indicates that the voltage is within an acceptable operating range at this point; otherwise Error is displayed.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Power Source
This field lists the power supply module(s) installed in the Switch (for example, PSU).
For CX4800-56F, PSU_1 is PWR1, and PSU_2 is PWR2. See Rear Panel for the location of the power supply modules.
Status
Active indicates the Switch is currently operating from the power source to which the power module is connected.
Present is displayed when the power module is connected to the Switch, but is not connected to a power source and there is no available power.
Absent is displayed when there is no power module connected to the Switch.
Error indicates that this power module is functioning below the power requirement. Or, the fan in this power module is not working.
Type
AC indicates the Switch is currently operating from an AC power source.
DC indicates the Switch is currently operating from a DC power source (DC models only).
*The following options are available for GS1915-8PDv2 only.
AF indicates the Switch is currently operating from an IEEE 802.3af (Type 1) power-up mode power source.
AT indicates the Switch is currently operating from an IEEE 802.3at (Type 2) power-up mode power source.
BT60 indicates the Switch is currently operating from an IEEE 802.3bt (Type 3 60 W) power-up mode power source.
BT90 indicates the Switch is currently operating from an IEEE 802.3bt (Type 4 90 W) power-up mode power source.
Hardware Monitor (Stacking Mode)
Slot
This number identifies the Switch in the stack. Click the number to see more detailed information on the Switch.
Name
This is the system name of the Switch in the stack.
Voltage
This shows if the power supply voltage sensor is within normal tolerance range.
Temperature
This shows if the temperature sensors on the Switch printed circuit board are within normal tolerance range.
Fan
This shows if the fan sensors are within normal tolerance range.
Power Supply
This shows if the Switch is properly operating from the connected power source.
Hardware Monitor (Stacking Mode)
This screen only appears when the Switch is in Stacking mode.
In the MONITOR > System Information > System Information screen, click an index of a Slot under Hardware Monitor to display the screen as shown. Use this screen to view hardware information of a specific slot (Switch) in your stacking system.
MONITOR > System Information > Hardware Monitor (Stacking Mode)
The following table describes the labels in this screen.
MONITOR > System Information > Hardware Monitor 
label
description
 
This displays the slot ID of the Switch in the stacking system.
Temperature Unit
The Switch has temperature sensors that are capable of detecting and reporting if the temperature rises above the threshold. You may choose the temperature unit: C (Centigrade) or F (Fahrenheit) in this field.
Temperature (C/F)
CPU, MAC, and BOARD refer to the location of the temperature sensors on the Switch printed circuit board. The first number represents the slot ID.
Status
This field displays Normal for temperatures below the threshold and Error for those above.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Fan Speed (RPM)
A properly functioning fan is an essential component (along with a sufficiently ventilated, cool operating environment) in order for the device to stay within the temperature threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed falls below the threshold shown. The first number represents the slot ID.
Status
Normal indicates that this fan is functioning above the minimum speed. Error indicates that this fan is functioning below the minimum speed.
Current
This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX
This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).
MIN
This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Voltage (V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if the voltage falls out of the tolerance range. The first number represents the slot ID.
Status
Normal indicates that the voltage is within an acceptable operating range at this point; otherwise Error is displayed.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Power Source
This field lists the power supply modules installed in the Switch. PSU_1 is PWR1, and PSU_2 is PWR2. The first number represents the slot ID.
Status
Active indicates the Switch is currently operating from the power source to which the power module is connected.
Standby indicates the power module is connected to a power source but the Switch is NOT operating from it.
N/A is displayed when the power module is not connected to a power source and there is no available power.