label | description |
|---|---|
System Information | |
System Name | This field displays the descriptive name of the Switch for identification purposes. |
Product Model | This field displays the product model of the Switch. Use this information when searching for firmware upgrade or looking for other support information in the website. |
FaOS F/W Version | This field displays the version number of the Switch 's current firmware including the creation date. |
Ethernet Address | This field refers to the Ethernet MAC (Media Access Control) address of the Switch. |
CPU Utilization Current (%) | CPU utilization quantifies how busy the system is. Current (%) displays the current percentage of CPU utilization. |
Memory Utilization Memory utilization shows how much DRAM memory is available and in use. It also displays the current percentage of memory utilization. | |
Name | This field displays the name of memory pool. |
Total (byte) | This field displays the total number of bytes in this memory pool. |
Used (byte) | This field displays the number of bytes being used in this memory pool. |
Utilization (%) | This field displays the percentage (%) of memory being used in this memory pool. |
Hardware Monitor | |
Temperature (C/F) | BOARD, MAC, CPU and PHY refer to the location of the temperature sensor on the Switch printed circuit board. |
Status | This field displays Normal for temperatures below the threshold and Error for those above. |
Current | This shows the current temperature at this sensor. |
MAX | This field displays the maximum temperature measured at this sensor. |
MIN | This field displays the minimum temperature measured at this sensor. |
Threshold | This field displays the upper temperature limit at this sensor. |
Fan Speed (RPM) | A properly functioning fan is an essential component (along with a sufficiently ventilated, cool operating environment) in order for the device to stay within the temperature threshold. Each fan has a sensor that is capable of detecting and reporting if the fan speed falls below the threshold shown. |
Status | Normal indicates that this fan is functioning above the minimum speed. Error indicates that this fan is functioning below the minimum speed. |
Current | This field displays this fan's current speed in Revolutions Per Minute (RPM). |
MAX | This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM). |
MIN | This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is displayed for speeds too small to measure (under 2000 RPM). |
Threshold | This field displays the minimum speed at which a normal fan should work. |
Voltage(V) | The power supply for each voltage has a sensor that is capable of detecting and reporting if the voltage falls out of the tolerance range. |
Status | Normal indicates that the voltage is within an acceptable operating range at this point; otherwise Error is displayed. |
Current | This is the current voltage reading. |
MAX | This field displays the maximum voltage measured at this point. |
MIN | This field displays the minimum voltage measured at this point. |
Threshold | This field displays the percentage tolerance of the voltage with which the Switch still works. |
Power Source | This field lists the power supply modules installed in the Switch. PSU_1 is PWR1, and PSU_2 is PWR2. |
Status | Active indicates the Switch is currently operating from the power source to which the power module is connected. Present is displayed when the power module is connected to the Switch, but is not connected to a power source and there is no available power. Absent is displayed when there is no power module connected to the Switch. Error indicates that this power module is functioning below the power requirement. Or, the fan in this power module is not working. |
Type | AC indicates the Switch is currently operating from an AC power source. DC indicates the Switch is currently operating from a DC power source (DC models only). AF indicates the Switch is currently operating from an IEEE 802.3af (Type 1) power-up mode power source. AT indicates the Switch is currently operating from an IEEE 802.3at (Type 2) power-up mode power source. BT60 indicates the Switch is currently operating from an IEEE 802.3bt (Type 3 60 W) power-up mode power source. BT90 indicates the Switch is currently operating from an IEEE 802.3bt (Type 4 90 W) power-up mode power source. |